Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 77
Filter
1.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 272-281, 2024.
Article in Chinese | WPRIM | ID: wpr-1006293

ABSTRACT

Xiaoyaowan has the effects of soothing the liver, invigorating the spleen, regulating menstruation, and nourishing blood. It is often used to treat the distending pain of the chest and hypochondriac, loss of appetite, dizziness, and irregular menstruation caused by liver depression and spleen deficiency. The formula originated from the Sinisan of Treatise on Cold Damage(《伤寒论》) in the Han dynasty and was officially formulated in the Song dynasty's Taiping Royal Prescriptions(《太平惠民合计局方》). In the Ming and Qing dynasties, it was developed into more comprehensive formulas such as modified Bazhentang, modified Xiaoyaowan, and other formulas. In recent years, Xiaoyaowan has become a classic formula for treating many symptoms of liver depression. The Pharmacopoeia of the People's Republic of China(《中华人民共和国药典》), 2020 edition, records Xiaoyaowan and modified Xiaoyaowan. Modern clinical research has further expanded the therapeutic range of this formula. Through literature research, it is found that there are certain reports on the clinical application and quality analysis of Xiaoyaowan, but the relevant literature lacks collation so far. Therefore, relevant literature was consulted and sorted out. The paper summarized the treatment of mammary hyperplasia, depression, irregular menstruation, melasma, menopausal syndrome, and polycystic ovary syndrome with Xiaoyaowan, as well as the quality analysis of paeoniflorin, ferulic acid, and glycyrrhizinic acid of Xiaoyaowan. It is expected to lay a foundation for further research on clinical application, pharmacodynamic mechanism, and quality control of this classic formula.

2.
International Eye Science ; (12): 648-654, 2023.
Article in Chinese | WPRIM | ID: wpr-965794

ABSTRACT

AIM:To observe the changes in corneal aberrations and the characteristics of visual quality after transepithelial photorefractive keratectomy(T-PRK)and femtosecond small incision lenticule extraction(SMILE)in the correction of low myopia.METHODS: Prospective cohort study. A total of 32 cases(32 eyes)with low myopia who underwent T-PRK surgery and 45 cases(45 eyes)of SMILE surgery at Weifang Eye Hospital from April 2021 to April 2022 were selected. The uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), spherical equivalent(SE), corneal higher-order aberrations(HOAs)and objective visual quality were compared between the two groups.RESULTS:All patients completed the surgery successfully without complications such as infection. At 3mo postoperatively, the safety index was 1.13±0.16 and 1.16±0.17(P=0.48)and the efficacy index was 1.10±0.20 and 1.15±0.18(P=0.27)in the T-PRK and SMILE groups, respectively. The percentage of UCVA(LogMAR)≤0 in the T-PRK and SMILE groups was 94% and 98%, respectively. The percentage of the residual SE within ±0.5D was 88% and 87% in the two groups, respectively. The HOAs and spherical aberration in both groups were significantly increased(P≤0.01), and the increase was not statistically significant between the two groups(P=0.31, 0.89). There was no significant change in horizontal coma, horizontal trefoil and vertical trefoil in both groups(P>0.05). The vertical coma in SMILE group was significantly increased(P<0.001), while there was no significant change in T-PRK group(P>0.05), and the increase was significantly greater in SMILE group than in T-PRK group(P<0.001). There was no significant difference in objective scattering index(OSI), modulation transfer function cut off frequency(MTFcut off), Strehl ratio(SR), visual acuity(VA)100%, VA20% and VA9% between the two groups(P>0.05).CONCLUSION:Both T-PRK and SMILE showed good safety, efficacy, and visual quality in correcting low myopia, while SMILE induced more vertical coma than T-PRK.

3.
International Eye Science ; (12): 567-572, 2023.
Article in Chinese | WPRIM | ID: wpr-965778

ABSTRACT

AIM: To investigate the short-term visual quality outcomes after femtosecond laser small incision lenticule extraction(SMILE)and evolution implantable collamer lens(EVO-ICL)implantation for the correction of moderate myopia.METHODS: Prospective control study. A total of 51 cases(51 eyes)with moderate myopia who underwent SMILE or EVO-ICL implantation surgery at Weifang Eye Hospital from April 2021 to February 2022 were selected. They were divided into SMILE group(30 patients, 30 eyes)and EVO-ICL group(21 patients, 21 eyes)according to the surgical methods. The changes of visual acuity [uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA)], diopter [spherical equivalent(SE)] and related parameters of optical quality analysis system(OQAS Ⅱ)were observed before surgery and at 1wk, 1 and 3mo after surgery, and the quality of vision(QoV)questionnaire was completed.RESULTS: At 3mo after surgery, the safety index(postoperative CDVA/preoperative CDVA)of SMILE gruop and EVO-ICL group were 1.20(1.00, 1.20)and 1.20(1.00, 1.38), respectively, the efficacy index(postoperative UDVA/preoperative CDVA)were 1.00(1.00, 1.20)and 1.00(1.00, 1.20), respectively, and the percentage of SE within ±0.50D was 87% and 100%, respectively. In SMILE group, the objective scattering index(OSI)was increased after surgery, while modulation transfer function cutoff frequency(MTF cutoff), contrast visual acuity(VA)100%, and VA20% at 1wk and 1mo after surgery, and Strehl ratio(SR)and VA9% at each time point after surgery were all decreased compared with those before surgery(all P<0.05). The OSI, MTF cutoff, SR and VA of EVO-ICL group showed no difference at each time point after surgery compared with those before surgery(all P>0.05). The most common visual symptoms after SMILE and EVO-ICL implantation were visual haze and halos, respectively.CONCLUSION: Both SMILE and EVO-ICL implantation have good safety, efficacy and predictability in the short term after the correction of moderate myopia. Both groups had visual symptoms after surgery, but the overall satisfaction of patients was high. Furthermore, EVO-ICL implantation has better objective visual quality performance.

4.
China Journal of Chinese Materia Medica ; (24): 908-920, 2023.
Article in Chinese | WPRIM | ID: wpr-970562

ABSTRACT

To clarify the content characteristics of the main active components and mineral elements of Cynomorium songaricum under different habitat conditions, and further explore the relationship between the quality of C. songaricum and habitats, this study took C. songaricum from 25 different habitats in China as the research object, and measured the contents of 8 main active components and 12 mineral elements separately. Diversity analysis, correlation analysis, principal component analysis and cluster analysis were carried out. The results showed that the genetic diversity of total flavonoids, ursolic acid, ether extract, potassium(K), phosphorus(P) and zinc(Zn) in C. songaricum was high. The coefficient of variation of crude polysaccharide, ether extract, gallic acid, protocatechuic aldehyde, catechin, epicatechin, calcium(Ca), sodium(Na), magnesium(Mg), sulfur(S), iron(Fe), manganese(Mn), selenium(Se) and nickel(Ni) were all over 36%, indicating that the quality of C. songaricum was significantly affected by habitats. There were strong synergistic and weak antagonistic effects among the contents of the 8 active components, and complex antagonistic and synergistic effects among the contents of the 12 mineral elements. Principal component analysis revealed that crude polysaccharide, ursolic acid, catechin, epicatechin and total flavonoids could be used as the characteristic components to evaluate the quality of C. songaricum, and Na, copper(Cu), Mn and Ni were the characteristic elements to evaluate the quality of C. songaricum. In cluster ana-lysis, the second group with the main active components as cluster center had better quality in terms of the content of active substances, and the second group with the mineral elements as cluster center had higher utilization potential in the exploitation of mineral elements. This study could provide a basis for resource evaluation and breeding of excellent varieties of C. songaricum in different habitats, and provide a reference for cultivation and identification of C. songaricum.


Subject(s)
Cynomorium , Catechin , Plant Breeding , Selenium , Ethers , Ethyl Ethers , Flavonoids , Plant Extracts
5.
China Tropical Medicine ; (12): 362-2023.
Article in Chinese | WPRIM | ID: wpr-979691

ABSTRACT

@#Abstract: Objective To further investigate the underreporting of mortality surveillance data among permanent residents in Hainan Province in 2020, and to explore the application of Application of the Analysis of National Causes of Death for Action (ANACONDA) in the quality analysis of mortality surveillance. Methods The data were collected from the Death Information Monitoring and Management System of Hainan Center for Disease Control and Prevention, and mainly included 33 418 deaths reported from 19 cities and counties in Hainan Province from January 1, 2020 to December 31, 2020. All the data were analyzed by the application of ANACONDA, and the causes of death were classified by the International Classification of Diseases, 10th Revision (ICD-10). Results A total of 33 418 deaths were reported in Hainan Province in 2020, with a crude mortality rate of 3.6‰. The proportion of deaths in males under 85 years old was higher than that in females, while the proportion of deaths in 85 years old and above was opposite. The quality analysis of cause of death surveillance showed that there was under-reporting of death surveillance in Hainan Province in 2020, with an under-reporting rate of 30.1%. There were differences in the age composition and GBD regional composition ratio of deaths of the three major categories of diseases, and the misreporting of causes of death in the middle and high age groups was more significant. The Vital Statistics Performance Index (VSPI) score of death data in Hainan Province in 2020 was 52.8, the score of cause of death reporting quality was 85.5, and the score of specific cause of death level that could be used was 88.4. The completeness of death reports in the priority action areas for improving cause of death data quality accounted for the largest share, followed by the quality of cause of death reports. There was a difference in the proportion of specific causes of death between males and females after the survey, but the change in order was not obvious. Conclusions The data integrity of cause-of-death surveillance is low in Hainan Province in 2020. It is suggested to improve the completeness of reporting data, strengthen the training of cause-of-death surveillance system, and regularly evaluate and supervise the system.

6.
Indian J Ophthalmol ; 2022 Jun; 70(6): 2107-2110
Article | IMSEAR | ID: sea-224364

ABSTRACT

Purpose: The present study was performed to compare the optical quality of the eyes of myopic children before and after treatment with atropine eye drops of different concentrations. Methods: In the study population of 71 patients (131 eyes), 34 patients (63 eyes) were given 0.01% atropine eye drops and 37 patients (68 eyes) were given 0.05% atropine eye drops. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs 100%, 20%, and 9%) under different lighting conditions were measured before and after two weeks of atropine treatment. Results: After using 0.05% atropine eye drops for two weeks, the Strehl ratio decreased from 0.27 ± 0.07 to 0.23 ± 0.07 (P = 0.0026), PVA 20% decreased from 1.15 ± 0.32 to 1.03 ± 0.36 (P = 0.0344), and PVA 9% decreased from 0.74 ± 0.23 to 0.64 ± 0.23 (P = 0.0073). The OSI was significantly higher after using 0.05% than 0.01% atropine eye drops (P = 0.0396), while both the Strehl ratio and PVA 20% were lower after using 0.05% than 0.01% atropine eye drops (P = 0.0087 and P = 0.0492, respectively). Conclusion: The children’s optical quality did not change significantly after using 0.01% atropine eye drops, whereas it decreased after using 0.05% atropine eye drops.

7.
Journal of Forensic Medicine ; (6): 470-478, 2021.
Article in Chinese | WPRIM | ID: wpr-985235

ABSTRACT

In recent years, as the third-generation of drugs, new psychoactive substances (NPS) have expanded rapidly and become a serious concern for China's anti-drug prevention and control system. As a new drug monitoring technology in the current anti-drug field, wastewater analysis is an objective, real-time, accurate, convenient and effective drug monitoring method. In recent years, it has gradually been applied to the monitoring of NPS. This study summarizes wastewater sample collection, target stability research, wastewater sample pretreatment, wastewater sample analysis methods, target NPS consumption calculations and actual monitoring applications, with a view to the construction of a monitoring system for NPS in wastewater, real-time and accurate grasp of information on the use of NPS in cities, the reflection of the actual consumption of different types of NPS and consumption trends in a short period of time, and prediction of the development trend of abused use, which is of great significance for combating NPS crimes, serving and guaranteeing the personal safety of the people, and maintaining social stability.


Subject(s)
China , Cities , Illicit Drugs/analysis , Psychotropic Drugs/analysis , Wastewater/analysis , Water Pollutants, Chemical/analysis
8.
International Eye Science ; (12): 339-343, 2021.
Article in Chinese | WPRIM | ID: wpr-862439

ABSTRACT

@#AIM:To evaluate optical quality, intraocular scatter, and determine the impact of retinopathy on optical quality in macular edema(ME)patient by using the Optical Quality Analysis System(OQAS<sup>TM</sup>Ⅱ).<p>METHODS: This was a prospective case-control study. Fifty-eight eyes of 49 macular edema patients who were confirmed by ophthalmic examination in our hospital from August 2019 to January 2020 were selected as the ME group, and 30 eyes of 30 healthy volunteers who were matched with gender and age range for the study were selected for the normal control group. The clinical data of the two groups of patients were recorded. Under the same test conditions, the same operator used OQAS<sup>TM</sup>Ⅱ to check the visual quality of the study object, including the cutoff of the modulation transfer function(MTF cutoff), strehl ratio(SR), OQAS<sup>TM</sup>Ⅱ values(100%, 20%, 9%)and contrast levels(OV100%, OV20%, OV9%). The difference of data between the two groups were analyzed, and the correlation between the visual quality and the thickness and volume of the macular fovea in the ME group were analyzed.<p>RESULTS: The average best corrected visual acuity in the macular edema group was significantly lower than the control group, and the thickness and volume of macular fovea were significantly higher than the control group(<i>P</i><0.001). Compared with the control group, the OSI of the macular edema group was significantly higher, and MTF cutoff, SR value, OV(100%, 20%, 9%)significantly decreased(<i>P</i><0.001). In the macular disease group, the thickness of macular fovea was positively correlated with OSI(<i>r</i>=0.566, <i>P</i><0.001), while MTF cutoff(<i>r</i>=-0.336, <i>P</i>=0.010), OV100%(<i>r</i>=-0.326, <i>P</i>=0.013), OV20%(<i>r</i>=-0.349, <i>P</i>=0.007)and OV9%(<i>r</i>=-0.321, <i>P</i>=0.014)were negative correlation, but it had no correlation with SR. In the macular edema group, the volume of macular fovea was positively correlated with OSI(<i>r</i>=0.574, <i>P</i><0.001). It was negatively correlated with MTF cutoff(<i>r</i>=-0.367, <i>P</i>=0.005), SR(<i>r</i>=-0.265, <i>P</i>=0.045), OV100%(<i>r</i>=-0.351, <i>P</i>=0.007), OV20%(<i>r</i>=-0.385, <i>P</i>=0.003)and OV9%(<i>r</i>=-0.375, <i>P</i>=0.004).<p>CONCLUSION: The optical quality of patients with macular edema is lower than the normal population, and the changes in macular retina morphology and thickness could affect the optical quality and intraocular scattering. The optical quality parameters measured by OQAS<sup>TM</sup>Ⅱ may provide new clinical reference for macular function evaluation.

9.
International Eye Science ; (12): 1086-1090, 2021.
Article in Chinese | WPRIM | ID: wpr-876761

ABSTRACT

@#AIM: To assess the accuracy of optical quality analysis system Ⅱ(OQAS Ⅱ)in predicting postoperative visual acuity of cataract patients.<p>METHODS: Prospective study, patients underwent cataract surgery in Daping Hospital from June 2019 to November 2019 were recruited. According to predicted visual acuity 100%(PVA100%)and best corrected visual acuity(BCVA), patients were dichotomized into group A(PVA100% worse than BCVA, 145 eyes)and group B(PVA100% equal to or better than BCVA, 114 eyes). Visual acuity improvement was compared between the two groups 1mo after surgery.<p>RESULTS: In group A, visual acuity of 112 eyes(77.2%)improved at least 2 lines. While in group B, 93 eyes(81.6%)improved at least 2 lines. There was no significant difference in visual acuity improvement ratio between the two groups(<i>P</i>=0.394). The average BCVA improvement of group A was 0.3(0.2, 0.4)LogMAR, and that of group B was 0.4(0.2, 0.5)LogMAR, revealed statistically significant differences(<i>P</i>=0.001). No significant correlation was found between preoperative PVA100% and postoperative BCVA in both of the two groups(<i>P</i>=0.888,0.304). In patients combined with preoperative ocular comorbidity, 17 eyes(94.4%)in group A and 26 eyes(65.0%)in group B improved at least 2 lines with significant difference between the two groups(<i>P</i>=0.041). BCVA improved 0.3(0.2, 0.4)LogMAR in group A and 0.3(0.1, 0.5)LogMAR in group B, there was no significant difference between the two groups(<i>P</i>=0.597).<p>CONCLUSION: The binary classification method based on the value of preoperative PVA100% and BCVA failed to accurately predict who shall benefit more from cataract surgery. In patients diagnosed with preoperative ocular comorbidity, BCVA is likely to be significantly improved if preoperative PVA100% were worse than BCVA. More data are needed to determine the clinical value of PVA100%.

10.
Journal of Pharmaceutical Practice ; (6): 186-190, 2021.
Article in Chinese | WPRIM | ID: wpr-875685

ABSTRACT

Objective To analyze the quality of the hospital preparation magnesium sulfate oral solution by using capability sixpack. Methods By using the capability sixpack of Minitab, the content of magnesium sulfate in the magnesium sulfate oral solution was used as an indicator to determine whether the magnesium sulfate composition reached a controlled state during the production process and whether the production process of magnesium sulfate oral solution was stable. Results The content of magnesium sulfate and the production process of magnesium sulfate oral solution was under control, but there were potential disadvantages. Based on the concept of risk management philosophy, The failure model and effect analysis (FMEA) were applied to the prospective management of potential risks. Conclusion The application of the capability sixpack in the quality analysis of the hospital preparation of magnesium sulfate oral solution is helpful for us to discover the potential risks under the controlled state of the production process, which is beneficial to the improvement of the preparation production process and the assurance of the quality of the preparation.

11.
International Eye Science ; (12): 722-725, 2020.
Article in Chinese | WPRIM | ID: wpr-815768

ABSTRACT

@#AIM: To analyze changes in objective visual quality before and after femtosecond laser <i>in situ</i> keratomileusis(FS-LASIK)and smart pulse technology-assisted transepithelial photorefractive keratectomy(SMART).<p>METHODS: Prospective study. We collected 50 cases(100 eyes)treated with FS-LASIK(FS-LASIK group)and another 50 cases(100 eyes)treated with SMART(SMART group)from the Ophthalmology Department of our hospital between October 2018 and December 2018 using Optical Quality Analysis System(OQAS)to measure objective scatter index(OSI), modulation transfer function cut off frequency(MTF cut off), strehl ratio(SR)before and after surgery.<p>RESULTS: In the FS-LASIK and SMART groups, the OSI values were higher in the 1 and 3mo after surgery, whereas the MTF cut off and SR were lower in the 1 and 3mo after surgery(<i>P</i><0.05). There was no statistical difference between the two groups in the objective visual quality index before and after 1mo(<i>P</i>>0.05). However, after 3mo, the OSI value of the FS-LASIK group was higher than the SMART group(0.88±0.28 <i>vs</i> 0.70±0.27, <i>P</i><0.001), whereas the SR was lower than SMART group(0.21±0.05 <i>vs</i> 0.24±0.05, <i>P</i>=0.002).<p>CONCLUSION: Both FS-LASIK and SMART caused an increase in the intraocular scattering index and a decrease in objective visual quality. However, the visual quality of the SMART group was generally better than that of the FS-LASIK group, and long-term visual quality was more dominant.

12.
International Eye Science ; (12): 103-106, 2020.
Article in Chinese | WPRIM | ID: wpr-777806

ABSTRACT

@#AIM: To compare the visual quality and visual related quality of life in cataract patients after implantation of diffractive aspheric bifocal IOL and single focus aspheric IOL. <p>METHODS: Retrospective non-randomized study was implemented. In clinical application 110 patients(176 eyes)underwent phacoemulsification combined with IOL from October 2016 to December 2017. In details, 56 cases(82 eyes)with diffractive aspheric bifocal IOL(ZEISS AT LISE 809M)and 54 cases(94 eyes)with single focus aspheric IOL(ZEISS CTA 603P), respectively. Three months after surgeries, the main evaluation indices were successively collected, which included visual, the optical quality analysis system(OQAS)of the MTF cutoff, the Strehl ratio, the OSI, the 100% visual acuity(VA), the 20% VA and the 9% VA, as well as the visual function related quality of life scale(NEI-VFQ-25).<p>RESULTS: 1)VA: there was no significant difference in the corrected distance visual acuity(CDVA)between the two groups(<i>P</i>>0.05). However, there existed significant difference in the near vision(<i>P</i><0.05); 2)Objective quality visual analysis(OQAS): there was significant difference in the OSI. Regarding the visual acuity of simulated contrast sensitivity between two groups, the 20% VA and 9% VA expressed significant difference(<i>P</i><0.01); 3)NEI-VFQ-25 questionnaire: there were no significant differences in overall health, general vision, eye pain, distant vision, peripheral vision, social function, color vision, dependence and mental health between the two groups(<i>P</i>=0.88, 0.08, 0.60, 0.36, 0.80, 0.18, 0.41, 0.07, 0.95). But there was significant difference in near vision and social role limitation between the two groups(<i>P</i><0.05).<p>CONCLUSION: The 809M intraocular lenses and the 603P intraocular lenses can improve the optical quality of patients after the surgeries. The former one can provide better near vision, but the OSI was higher than the latter one, which may cause some visual interference. There was no significant difference in visual related quality of life after the surgeries generally.

13.
Chinese Herbal Medicines ; (4): 3-13, 2020.
Article in Chinese | WPRIM | ID: wpr-842037

ABSTRACT

In recent years, the development of Chinese herbal medicine (CHM) has been challenged by shortages of CHM resources and drug safety concerns related to end products. There have been significant efforts by Chinese scholars to tackle these challenges, which are revealed by analyzing the research trend of CHM resources via surveying Chinese Traditional and Herbal Drugs (Zhong Cao Yao), a representative journal in CHM. Our study focused on 781 articles in CHM resources from 2013 to 2018 and included four subject areas: germplasm resources, quality analysis and evaluation, cultivation, and bioengineering of CHM. Discussion and prospective for future investigations were also presented, including: construct the core germplasm of medicinal plants and expand germplasms; combine molecular research with field experiments and promote the deeper study of cultivation of CHM plants; improve the quality evaluation method of CHM and strengthen the identification of Chinese patented medicines; promote the sustainable development of CHM resources by utilizing bioengineering and synthetic biology. This study helps international scholars understand the status quo of CHM research and provides theoretical support for the healthy, modern, and international development of CHM, and it will facilitate the sustainable development of the traditional Chinese medicine industry.

14.
Article | IMSEAR | ID: sea-202538

ABSTRACT

Introduction: Quality control of blood and its componentsensures the availability of high quality product with maximumefficacy and minimal risk to recipients. As per standardguidelines, for quality assurance of FFP, 1% of all the unitsprepared or 4 units per month are tested for stable coagulationfactors: Factor VIII and Fibrinogen levels.Material and methods: The retrospective data was collectedfrom archives of blood bank from the period of 1st January2017 to 31st December 2017 in AIMSR, Bathinda. Out oftotal 3476 units collected, 2155 were processed for componentseparation. 1.9% of Fresh Frozen plasma (41/2155) were testedfor total volume, fibrinogen content and factor VIII levels forquality control with the help of semi-automated coagulometer.Results: 97.5% of FFP samples tested had factor VIII levelsabove 0.7 IU/mL and 100% of samples had fibrinogen content>200mg/dl.Conclusion: It is concluded that quality of FFP being preparedat our blood bank meets the international standards. Regularquality evaluation and maintenance of records helps to keepup the working standards and any deficiency can be checkedand curtailed.

15.
Chinese Pharmaceutical Journal ; (24): 1882-1887, 2019.
Article in Chinese | WPRIM | ID: wpr-857857

ABSTRACT

OBJECTIVE: To analyze and evaluate the quality status of Yigan Jiedu Capsules for providing evidence for its standard improvement and standardized production. METHODS: According to the problems found in the standard test, combined with the quality status of the original medicinal materials, exploratory research was carried out from the aspects of authenticity, safety, consistency and effectiveness of the drug, and a number of detection methods were established to analyze the quality of the preparations and the original medicinal materials. RESULTS: The qualified rate of inspection was 99.2%. The results of exploratory research indicated that some manufacturers may have problems such as false material feeding and insufficient material feeding. CONCLUSION: The overall quality of Yigan Jiedu Capsules is generally good, and the quality standard needs to be improved.

16.
Chinese Traditional and Herbal Drugs ; (24): 3329-3336, 2019.
Article in Chinese | WPRIM | ID: wpr-850978

ABSTRACT

Objective: To analyze the quality of Angelicae Dahuricae Radix (ADR) from national drug evaluation sampling, continuously improve and revise the standard determination method, and ensure the safety of public drug use, six index components of ADR medicinal material and decoction pieces were determined by combining HPLC fingerprint chromatography and quantitative analysis of multi-components by single marker (QAMS). Methods: The determination and exploratory study were carried out according to the National Standard. The establishment of steamed Angelicae dahurica HPLC fingerprint, method for multiple assessment of six index components to conduct a methodological survey determination of multi-index component content of 20 batches of Angelicae dahurica tablets, the final determination of the quality of Angelicae dahurica. Result:s A total of 239 batches of ADR were received from 189 enterprises, in which 225 batches were qualified and 14 batches were unqualified. The qualified rate was 94%. A method that determined content of six kinds of coumarin in ADR decoction pieces using imperatorin as control was established, which could solve the problem of difficulty in obtaining control and consuming long determination time. It would better indicate the drug quality. Conclusio:n The method we had established could be used in qualitative and quantitative analysis of oxypeucedanin hydrate, byakangelicin, oxypeucedanin, berapten, imperatorin and isoimperatorin in ADR decoction pieces. Through this random inspection, it is found that there were still some quality problems in ADR decoction pieces. The quality supervision of traditional Chinese medicine should be strengthened further.

17.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 209-218, 2019.
Article in Chinese | WPRIM | ID: wpr-801988

ABSTRACT

Houpo Wenzhongtang was contained in Neiwaishang bianhuolun.It was composed of seven medicinal materials of Magnoliae Officinalis Cortex(processed with ginger),Citri Reticulatae Pericarpium(remove white sac),Glycyrrhizea Radix et Rhizoma(processed with honey),Alpiniae Katsumadai Semen,Poria,Aucklandiae Radix and Zingiberis Rhizoma.It was a classic prescription for treatment of deficient cold of spleen and stomach,distention of chest and abdomen,autumn and winter guest cold crime stomach and feel pain at times by LI Dongyuan,who was a famous doctors in Jin-Yuan dynasties.It has been included in the Catalogue of Ancient Classical Prescription(The First Batch) issued by the State Administration of Traditional Chinese Medicine in 2018.This paper systematically reviewed the relevant research progress of Houpo Wenzhongtang from the aspects of famous doctors' theory,usage and dosage,chemical composition,quality analysis,pharmacology and toxicology,clinical application in database,and to provide a reference for further exerting the clinical application of this classical prescription.

18.
International Eye Science ; (12): 870-873, 2019.
Article in Chinese | WPRIM | ID: wpr-735225

ABSTRACT

@#AIM: To evaluate the early postoperative efficacy of SMART for myopia and compare it with TransPRK.<p>METHODS: Retrospective non-randomized controlled study. Totally 120 eyes of 60 patients with myopia who underwent SMART and TransPRK in our hospital from January to August 2018 were selected respectively. The uncorrected visual acuity(UCVA), visual quality, pain score, corneal epithelial healing and subepithelial haze were compared between two groups.<p>RESULTS: There was no statistical differences between two groups regarding the proportion of UCVA reaching or exceeding 1.0 at 5d, 1mo and 3mo after operation(<i>P</i>>0.05), but the visual quality of SMART group was better than that of TransPRK group at 5d after operation(<i>P</i><0.05), and with the prolongation of time, the visual quality of the two groups gradually improved. There was a significant difference in pain scores between the TransPRK group and SMART group(3.56±0.96 <i>vs</i> 3.07±1.07; 1.22±0.61 <i>vs</i> 0.84±0.59)on the 1st day and 3rd day after operation(<i>P</i><0.01). 5d after operation, the complete recovery rate of corneal in TransPRK group was lower than that in SMART group(69.2% <i>vs</i> 83.3%, <i>P</i><0.05). At 1st and 3 mo after operation, there was no difference in haze between the two groups(5.0% <i>vs</i> 5.0% and 8.3% <i>vs</i> 10.0%; <i>P</i>>0.05).<p>CONCLUSION: There is no significant difference between SMART and TransPRK in the speed and stability of visual acuity recovery, but the early postoperative pain of SMART is lighter, the corneal epithelium is healed faster, and the visual quality is better.

19.
International Eye Science ; (12): 834-836, 2019.
Article in Chinese | WPRIM | ID: wpr-735214

ABSTRACT

@#AIM: To evaluate the accuracy of qualitative prediction of cataract surgery by double-pass optical quality analysis system(OQASTMⅡ).<p>METHODS: A retrospective study was conducted. Totally 57 cataract patients(67 eyes)were randomly selected from October 2018 to December 2018 in Renmin Hospital of Wuhan University. According to the objective scattering index(OSI), they were divided into group A(28 eyes, OSI>8.0), group B(28 eyes, OSI≤8.0), and group C(11 eyes, OSI could not be detected due to severe lens opacity). The effect of surgery was predicted by Predicted VA100% and preoperative BCVA.<p>RESULTS: In group A, 26 eyes(93%)comply with the standard, and in group B, 24 eyes(86%)comply with the standard. There was no significant difference between the two groups(<i>P</i>=0.669). Besides, no correlation was found between Predicted VA100% and postoperative 2wk BCVA(<i>r</i><sub>s</sub>=0.103, <i>P</i>>0.5).<p>CONCLUSION: The OQASTMⅡ system can objectively, accurately and intuitively predict the effect of cataract surgery.

20.
International Eye Science ; (12): 1928-1930, 2019.
Article in Chinese | WPRIM | ID: wpr-756888

ABSTRACT

@#AIM: To evaluate the clinical efficacy of the posterior chamber intraocular lens(ICL)implantation for high myopia by the double-pass optical quality analysis system II(OQAS II).<p>METHODS: A total of 26 eyes of 52 patients with high myopia admitted to the First Affiliated Hospital of Anhui Medical University from December 2017 to December 2018 were selected. All patients underwent ICL implantation. Follow-up to obtain the best corrected visual acuity(BCVA)of all patients. And a series of parameters, such as uncorrected visual acuity(UCVA), object scatter index(OSI), modulation transfer function(MTF), Strehl ratio(SR)and Predicted VA of 100%,20% and 9%,were obtained before and 1wk,1 and 3mo after operation.<p>RESULTS: Compared with preoperative UCVA and BCVA, the 1wk, 1 and 3mo UCVA were better than preoperative and gradually improved, and the differences were statistically significant(<i>P</i><0.01). Compared with OSI, MTF, SR and Predicted VA 100%, 20% and 9% before operation, the situation improved at 1wk,1 and 3mo after operation, with statistical significance(<i>P</i><0.01).<p>CONCLUSION: ICL implantation can effectively correct high myopia and improve UCVA. Through OQAS II analysis, OSI was reduced after ICL implantation. The postoperative MTF, SR and Predicted VA of 100%, 20% and 9% higher than those before surgery. The visual quality of patients with high myopia was improved after ICL implantation.

SELECTION OF CITATIONS
SEARCH DETAIL